AC-coupled vs DC-coupled battery: one day
Enter one day of hourly array DC power and home load. It compares where the energy goes in the two layouts.
Hourly profiles (kWh per hour)
Settings
Defaults: 90% is the AC round trip on the Enphase IQ Battery 5P and Tesla Powerwall 2 AC sheets. 89% is Tesla's Powerwall 3 solar-to-battery-to-home figure. 97% is the Enphase IQ8+ CEC weighted efficiency, used here for either inverter. Battery size and power are assumptions.
| Day total (kWh) | AC-coupled | DC-coupled |
|---|---|---|
| Array DC energy | - | - |
| Clipped (lost) | - | - |
| Direct to the home | - | - |
| Battery to the home | - | - |
| Exported | - | - |
| Imported from the grid | - | - |
| Solar to battery to home (end to end, %) | - | - |
| Grid to battery to home (end to end, %; DC is our estimate) | - | - |
Method: hourly steps, load first, then battery, then export. AC-coupled: the PV inverter passes at most the AC limit, so clipped energy is lost, and the battery charges from AC. DC-coupled: the battery charges from the DC bus. The DC-coupled grid-charging figure is an estimate: the solar figure times the inverter efficiency. Hourly data hides short clipping spikes. Not the standard text or any manufacturer's tool; check the datasheets.