C-rate calculator
Turn a power into a C-rate on nominal and usable kWh, then find which limit sets the power in a battery and inverter pairing.
Read this first. The defaults reproduce the page example: Pylontech US5000 datasheet figures and a Sunsynk 5 kW inverter's printed limits, in a hypothetical pairing. They are not a compatibility claim. Power is taken as amps times nominal voltage, with no losses or voltage sag. Parallel current limits are assumed to add. Use a dot for decimals; "10,000" is read as ten thousand.
1. C-rate from a power
| Result | Value |
|---|---|
| Capacity in amp-hours at this voltage (nominal kWh ÷ volts) | - |
| Current at that power (kW ÷ volts) | - |
| C-rate on nominal energy | - |
| C-rate on usable energy | - |
| Hours to deliver the usable energy at this power | - |
2. Which limit sets the power?
| Result | Value |
|---|---|
| Battery limit (modules × amps × volts) | - |
| Inverter DC limit (amps × volts) | - |
| Inverter AC rating | - |
| Lowest limit, and what sets it | - |
| C-rate at that power, nominal and usable | - |
| Hours to deliver the usable energy | - |
Method: C-rate = power ÷ energy, which equals amps ÷ amp-hours only while voltage stays at the nominal value. Power limit = the lowest of modules × amps × volts, inverter amps × volts, and the inverter AC rating. Which current figure to use (recommended or maximum) is the maker's choice to confirm.