C-rate calculator

Turn a power into a C-rate on nominal and usable kWh, then find which limit sets the power in a battery and inverter pairing.

Read this first. The defaults reproduce the page example: Pylontech US5000 datasheet figures and a Sunsynk 5 kW inverter's printed limits, in a hypothetical pairing. They are not a compatibility claim. Power is taken as amps times nominal voltage, with no losses or voltage sag. Parallel current limits are assumed to add. Use a dot for decimals; "10,000" is read as ten thousand.

1. C-rate from a power

ResultValue
Capacity in amp-hours at this voltage (nominal kWh ÷ volts)-
Current at that power (kW ÷ volts)-
C-rate on nominal energy-
C-rate on usable energy-
Hours to deliver the usable energy at this power-

2. Which limit sets the power?

ResultValue
Battery limit (modules × amps × volts)-
Inverter DC limit (amps × volts)-
Inverter AC rating-
Lowest limit, and what sets it-
C-rate at that power, nominal and usable-
Hours to deliver the usable energy-

Method: C-rate = power ÷ energy, which equals amps ÷ amp-hours only while voltage stays at the nominal value. Power limit = the lowest of modules × amps × volts, inverter amps × volts, and the inverter AC rating. Which current figure to use (recommended or maximum) is the maker's choice to confirm.