Solar software glossary
Plain answers to the solar and software terms installers, designers and sales teams meet every day.
269 terms in 17 categories. 257 come with a free calculator.
Most-referenced terms
The terms other glossary pages link to most. A good place to start.
- Performance Ratio (PR) Performance ratio (PR, also called quality factor) is the AC energy a PV system delivers divided by the ideal output at its nameplate rating.
- Solar Operations and Maintenance (O&M) Solar O&M (operations and maintenance) is the monitoring, inspection and repair work that keeps a PV plant producing.
- STC (Standard Test Conditions) Standard test conditions (STC) are the lab conditions used to rate a solar module.
- Degradation Rate Degradation rate is the yearly fall in a PV module’s or system’s output, usually given in percent per year.
- Solar Site Survey A solar site survey (also called site assessment) is the on-site, remote or drone check of roof, electrical service and shade before design.
- Application Programming Interface (API) An application programming interface (API) is a set of documented web requests that let one program read or write another program’s data.
- Bill of Materials (BOM) Bill of materials (BOM, also called a material list) is the list of every part a solar job needs, with a unit and quantity.
- Equipment Datasheet (Spec Sheet) An equipment datasheet (spec sheet, also called a cut sheet) is the manufacturer’s document of one product’s rated values, limits and listings.
Showing all 269 terms
Design and layout 26
- 3D Solar Modelling 3D solar modeling builds a scaled digital copy of a roof, its obstructions, nearby trees and terrain, with a position and height for each object.
- Aerial Imagery in Solar Design Aerial imagery is overhead photography from aircraft, satellites or drones that solar designers trace roofs on.
- AI Auto Design AI auto design (or auto-layout) is software that proposes a draft solar array layout from roof planes, obstructions, setback values and a target size.
- Azimuth Azimuth (also called orientation or bearing) is the compass direction a solar module faces, in degrees around the horizon.
- Backtracking in Solar Trackers Backtracking is a single-axis tracker mode that rotates rows back toward flat in the early morning and late afternoon so one row’s shadow never lands…
- Bifacial Modelling Bifacial modelling (also called bifacial gain simulation) estimates the extra energy a bifacial module makes from rear-face light.
- Bill of Materials (BOM) Bill of materials (BOM, also called a material list) is the list of every part a solar job needs, with a unit and quantity.
- Bill of Quantities (BoQ) Bill of quantities (BoQ, also written BOQ or BQ) is an itemised list of project work and materials with units and quantities.
- BIM (Building Information Modelling) and Revit BIM (building information modelling) is a 3D building model.
- CAD (DWG and DXF Files) CAD files (computer-aided design drawings, mostly DWG and DXF) store a drawing as layers, blocks and geometry in one stated unit.
- Carport Solar Design Carport solar design (also called solar canopy design) is laying out PV modules on a raised steel frame over parking spaces.
- Design Accuracy (Design Validation) Design accuracy is how closely a solar design matches the system as built.
- Drone Site Survey (Photogrammetry) A drone site survey (photogrammetry) turns overlapping drone photos into a 3D surface model and to-scale map of a roof or site.
- Ground Coverage Ratio (GCR) Ground coverage ratio (GCR) is the ratio of module area to the ground area allotted to it.
- Keep-Out Zone (Obstruction) A keep-out zone (also called an exclusion zone) is an area where no modules are placed, such as around vents, skylights, chimneys or wetlands.
- LiDAR (Light Detection and Ranging) LiDAR (light detection and ranging) times laser pulses to measure distance, then builds a cloud of 3D points.
- Remote Site Assessment Remote site assessment (or remote site survey) means judging a solar site from aerial imagery, 3D models and customer photos without a visit.
- Roof Measurement Roof measurement (also called roof measuring) is recording the size, pitch and azimuth of each roof plane before solar design.
- Row Spacing and Pitch Row pitch is the distance from the front edge of one row of tilted modules to the front edge of the next.
- Single-Axis Tracker A single-axis tracker is ground-mount racking that rotates rows of modules about one axis, usually north-south, to follow the sun from east to west.
- SketchUp Solar Plug-in A SketchUp solar plug-in (also called a SketchUp solar extension) is an add-on that gives SketchUp, a general 3D modeller, photovoltaic tools.
- Solar Design Software Solar design software, also called PV design software, turns a site and an energy need into a buildable PV design.
- Solar Panel Layout A solar panel layout, also called a module layout, is the plan for where each PV module sits on a roof or site.
- Solar Site Survey A solar site survey (also called site assessment) is the on-site, remote or drone check of roof, electrical service and shade before design.
- Structural Loading on a Solar Array Structural loading on a solar array is the set of forces the array adds to, or must resist on, its roof or frame: dead load (weight), live, snow…
- Tilt Angle Tilt angle (also called module tilt or slope) is the angle between a solar module and the horizontal.
Storage and hybrid systems 24
- AC Coupling vs DC Coupling AC coupling and DC coupling describe where a battery joins solar.
- Backup Power and Critical-Load Design Backup power (also called critical-load backup) is battery or generator supply that keeps chosen circuits running when the grid fails.
- Battery Cycle Life Battery cycle life is the number of charge-discharge cycles a battery completes before its capacity falls to a stated end-of-life level, such as 70%…
- Battery Energy Storage System (BESS) A battery energy storage system (BESS) is a battery plus the equipment that converts, controls, cools and protects it.
- Battery Management System (BMS) A battery management system (BMS) is the control electronics inside a solar battery pack, with 4 main jobs.
- Behind-the-Meter (BTM) Behind-the-meter (BTM) means solar, storage or load wired on the customer’s side of the utility’s service meter.
- C-Rate C-rate is a battery’s charge or discharge current divided by its amp-hour capacity, or roughly its kW divided by its kWh.
- Charge Controller A charge controller (also called a solar charger) sits between an array and a battery.
- Demand Charge Management Demand charge management is controlling a site’s highest kW draw so the utility bills less for demand.
- Demand Response (DR) Demand response (DR) is a customer cutting electricity use below normal when the grid is stressed or prices spike, for a payment or a lower rate.
- Depth of Discharge (DoD) Depth of discharge (DoD) is the share of a battery’s capacity that has been used, from 0% when full to 100% when empty.
- Distributed Energy Resource (DER) A distributed energy resource (DER) is a power source, battery or controllable load on the local distribution grid or behind a customer’s meter.
- Distributed Energy Resource Management System (DERMS) DERMS (distributed energy resource management system, or DER management system) is software that monitors, forecasts and dispatches groups of solar…
- Energy Arbitrage Energy arbitrage is charging a battery when electricity is cheap and using or selling that energy when it costs more.
- EV Charger Integration EV charger integration (also called solar EV charging) is connecting an EV charger to a solar and storage system.
- Hybrid Inverter A hybrid inverter (also called a hybrid solar inverter) converts DC from panels and a battery to AC and charges the battery, in one unit.
- LFP (Lithium Iron Phosphate) Battery An LFP battery (lithium iron phosphate, also called LiFePO4) is a lithium-ion battery with an iron-phosphate positive electrode.
- Microgrid Design Microgrid design (also called microgrid sizing) is picking equipment for loads that run with the grid or alone: solar, storage, a generator and…
- Peak Shaving Peak shaving is cutting the highest kW a site draws from the grid, usually by discharging a battery during the worst intervals.
- Round-Trip Efficiency Round-trip efficiency (RTE, also called round-trip energy efficiency) is the energy a storage system gives out divided by the energy put in, as a…
- Solar-Plus-Storage Solar-plus-storage (also called solar plus battery) is a PV array paired with a battery behind one grid connection.
- State of Charge (SOC) State of charge (SOC) is the energy stored in a battery as a percentage of a stated capacity, from 0% empty to 100% full.
- Time-of-Use (TOU) Optimisation Time-of-use (TOU) optimisation is scheduling battery charging, battery discharging and flexible loads against a time-of-use tariff.
- Virtual Power Plant (VPP) A virtual power plant (VPP) is a software-run group of home batteries, solar systems and EV chargers.
Solar basics 22
- Air Mass and Solar Spectrum (AM) Air mass (AM, also called optical air mass) is how much atmosphere sunlight crosses, compared with the shortest path.
- Anti-Reflection Coating (ARC) Anti-reflection coating (ARC) is a thin clear layer on solar cells or module glass that cuts the light a surface reflects, so more reaches the cell.
- Backsheet and EVA Encapsulant Backsheet and EVA encapsulant are two polymer parts of most solar module laminates.
- DC Disconnect (DC Isolator) A DC disconnect (a DC isolator in the UK and EU) is a manual switch that opens the DC circuit between PV strings and the inverter or battery.
- Distributed Generation (DG) Distributed generation (DG) is electricity produced at or near where it is used, such as rooftop solar, or by small plants on the local distribution…
- Fill Factor (FF) Fill factor (FF) is a solar cell or module’s maximum power divided by the product of its open-circuit voltage and short-circuit current.
- Grid Parity Grid parity (also called socket parity) is when the cost of 1 kWh from solar, its LCOE, is at or below the grid price.
- Grid-Connected (Grid-Tied) System A grid-connected (grid-tied) system is a solar PV array whose inverter feeds a building and the utility grid in parallel.
- Kilowatt (kW) and a Megawatt (MW) A kilowatt (kW, 1,000 watts) and a megawatt (MW, 1,000 kW) measure power, the rate of producing or using energy.
- Kilowatt-Hour (kWh) A kilowatt-hour (kWh, also written kW·h) is the energy that 1 kW of power uses or makes in 1 hour.
- Kilowatt-Hour and Megawatt-Hour (kWh and MWh) A kilowatt-hour (kWh) is the energy of 1 kW running for 1 hour.
- Net Zero Net zero means a building or organisation balances what it adds against what it takes out or exports over a set period, often 12 months.
- Nominal Voltage Nominal voltage is the approximate voltage used to name a cell, battery, module or system.
- Peak Load and Base Load Peak load is the highest site demand in a period, in kW.
- Photovoltaic (PV) Photovoltaic (PV) describes technology that turns sunlight directly into DC electricity in a semiconductor such as silicon, with a 1.12 eV gap.
- Rooftop Solar Rooftop solar (also called roof-mounted PV) is a PV array fixed to a building’s roof rather than the ground, on homes and commercial buildings alike.
- Solar Array A solar array, also called a PV array, is a group of PV modules wired to work as one power-producing unit.
- Solar Cell A solar cell, also called a photovoltaic or PV cell, is a single semiconductor device that turns light into direct current.
- Solar Farm A solar farm, also called utility-scale solar, is a ground-mounted PV plant built to sell power to the grid rather than supply one building.
- Solar Zenith and Incidence Angle Solar zenith angle is the sun’s angle from straight up.
- Thin-Film Solar Thin-film solar is a module type made by depositing thin semiconductor layers on glass, metal or plastic instead of cutting silicon wafers.
- Watt, Volt and Amp (W, V, A) Watt, volt and amp (W, V and A) are the three units that describe a solar circuit: power, electric potential difference (voltage) and current.
Electrical design 19
- Anti-Islanding Anti-islanding is the inverter protection that stops a solar system feeding power into a section of grid the utility has cut off.
- Arc-Fault Protection (AFCI) Arc-fault protection (AFCI) is a function, usually built into the inverter, that detects an electric arc in a solar system’s DC wiring and stops the…
- Busbar 120% Rule The busbar 120% rule (also called the 120% rule) limits solar backfeed into a main panel on US load-side connections.
- Combiner Box A combiner box (also called a PV or string combiner) is an enclosure that joins several parallel PV strings into one protected DC output.
- Grounding (Earthing) Grounding (earthing in UK and IEC documents) connects a PV system’s exposed metal, and in some designs one circuit conductor, to earth.
- Main Panel Upgrade (MPU) A main panel upgrade (MPU, also called a service panel upgrade) replaces or enlarges a main panel or service equipment to add capacity.
- Maximum Power Point Voltage and Current (Vmp and Imp) Maximum power point voltage and current (Vmp and Imp, also written Vmpp and Impp) are where a solar module gives its highest power.
- Microinverter A microinverter (also called a module-level inverter) is a small inverter that converts DC to AC at 1 or 2 solar modules.
- MLPE (Module-Level Power Electronics) MLPE (module-level power electronics) is hardware fitted to each solar module, or each pair, that tracks, converts or switches off that module on its…
- MV/LV Design (Medium and Low Voltage) MV/LV design is planning a solar plant’s AC network on both sides of each inverter transformer.
- NEC 690 Electrical Code Compliance NEC 690 electrical code compliance means a solar PV system meets Article 690 of the National Electrical Code (NFPA 70).
- Open-Circuit Voltage and Short-Circuit Current (Voc and Isc) Open-circuit voltage (Voc) is the voltage a solar module gives when no current flows.
- Overcurrent Protection (OCPD) Overcurrent protection (the overcurrent protective device, or OCPD) is a fuse or breaker that opens a circuit when current passes its rating.
- Power Factor and Reactive Power Power factor and reactive power describe how much of an inverter’s apparent power (kVA) does useful work.
- Power Optimiser A power optimizer (UK: optimiser) is a small DC-DC converter fitted to each solar module.
- Rapid Shutdown Rapid shutdown is a safety function that de-energises rooftop PV wiring so firefighters can work on the roof.
- Substation Design (Solar Collector and Interconnection Substation) Substation design is the engineering of a solar plant’s collector substation, where medium-voltage feeders step up to the grid.
- Voltage Drop Calculation Voltage drop calculation (also called cable voltage loss) finds how many volts a cable loses as current flows through its resistance.
- Wire and Conductor Sizing Wire and conductor sizing means choosing the smallest wire whose current rating still covers a circuit after derating.
Financial modelling and incentives 19
- Capital Expenditure (CAPEX) and Operating Expenditure (OPEX) Capex (capital expenditure) is the upfront cost to build a solar system: modules, inverters, racking, labour, permits and interconnection, paid at…
- Cash Flow Analysis Cash flow analysis is a year-by-year table of the money a solar project brings in and pays out, with a running total.
- Community Solar Community solar is a shared solar project whose output is split among many subscribers who cannot put panels on their own roof.
- Debt Sizing and DSCR Debt sizing finds the largest loan that a project’s cash flow can repay.
- Internal Rate of Return (IRR) Internal rate of return (IRR) is the discount rate at which the net present value of a project’s cash flows, from year 0 onward, is zero.
- Investment Tax Credit (ITC) The investment tax credit (ITC) is a US federal credit for business-owned solar and storage, now under section 48E.
- MACRS Depreciation (Modified Accelerated Cost Recovery System) MACRS depreciation (Modified Accelerated Cost Recovery System) is the US tax method for deducting the cost of business property over a set recovery…
- Net Billing (Export Tariff) Net billing is a solar tariff that prices power you import at the retail rate and credits power you export at a separate export rate, usually lower.
- Net Present Value (NPV) Net present value (NPV) is the sum of a solar project’s yearly cash flows, each divided by (1 + r)^t, minus the upfront cost.
- Payback Period Payback period (also called payback time) is the number of years a solar system’s savings take to repay its net cost.
- Project Finance Model A project finance model is a cash flow model of one project company.
- Renewable Energy Certificate (REC or SREC) A renewable energy certificate (REC, also called a renewable energy credit) is a tradable record.
- Return on Investment (ROI) in Solar Return on investment (ROI) is the net gain from an investment divided by its cost, shown as a percentage.
- Solar Financial Modelling Solar financial modelling (also spelled modeling) is the year-by-year model that turns a PV system’s energy yield into cash flow, IRR, NPV, payback…
- Solar Incentive or Rebate A solar incentive or rebate is a government, state or utility benefit that cuts a system’s net cost or pays for its output.
- Solar Lease A solar lease is a contract where a company installs solar on a home or business and the customer pays a set amount, usually monthly, to use it.
- Solar Loan A solar loan is money borrowed to buy a solar system and repaid in scheduled payments with interest.
- Third-Party Ownership (TPO) Third-party ownership (TPO) means a company other than the site host owns the solar system on the host’s roof or land.
- Utility Rate Escalation Utility rate escalation is the yearly percentage rise a solar savings model assumes in the customer’s power price.
Software and platform 19
- Application Programming Interface (API) An application programming interface (API) is a set of documented web requests that let one program read or write another program’s data.
- Cloud-Based vs Desktop Software Cloud-based vs desktop software is the choice between solar tools that run in a web browser and tools installed on your computer.
- Company Lock-In Company lock-in (also called software lock-in) is when leaving a company costs so much that you stay, even if a better option exists.
- Credit in Solar Software Pricing Credits (usage or consumption credits) are prepaid units that a solar software company sells in packs.
- Data Export (Data Portability) Data export (data portability) means you can take your records out of a tool in a form other tools can open.
- Free Plan vs Free Trial: What Is the Difference? Free plan vs free trial: a free plan has no end date but caps users, jobs or features.
- Integration (and an Integration Marketplace) An integration (also called a connector) is a link that moves data between two software tools, so nobody retypes it.
- Mobile App Offline Mode Mobile app offline mode (also called offline-first) lets a solar crew survey, install or inspect with no signal.
- Onboarding / Implementation in Solar Software Onboarding or implementation is the work of getting new software running in a solar company, up to go-live.
- Open-Source Solar Software Open-source solar software is solar design, modelling or monitoring code published under a licence that lets anyone use, change and share it.
- Per-Seat (Per-User) Pricing Per-seat (per-user) pricing charges a fixed fee for each person with a login, however many projects you run, so cost rises with headcount, not sales.
- pvlib python pvlib python is a free, open-source Python library for modelling the performance of PV systems.
- Quote-Only Pricing in Solar Software Quote-only pricing (also called contact-sales or custom pricing) means a company shows no price for a plan and gives one only after you ask.
- SaaS (Software as a Service) SaaS (software as a service) is software the company hosts and you rent by subscription.
- Single Sign-On (SSO) Single sign-on (SSO) lets staff reach many apps with one login held at an identity provider.
- Software-Agnostic / Hardware-Agnostic Software-agnostic and hardware-agnostic describe a platform that works with products from more than one maker.
- User Roles and Permissions User roles and permissions set what each login can see and change.
- Webhook A webhook (also called an HTTP callback) is an automatic web request that one system sends to your URL when an event happens.
- White-Labelling White-labelling (also white label or white labeling) is when a software company lets another company sell or run its product under its own brand.
Shading and solar resource 18
- Albedo Albedo (also called ground reflectance) is the fraction of incoming sunlight that a surface reflects, from 0 to 1.
- Diffuse Horizontal Irradiance (DHI) Diffuse horizontal irradiance (DHI, also called sky or diffuse radiation) is sunlight scattered by the atmosphere that reaches a flat, level surface…
- Direct Normal Irradiance (DNI) Direct normal irradiance (DNI, also called beam irradiance) is sunlight coming straight from the sun, in W/m².
- Global Horizontal Irradiance (GHI) Global horizontal irradiance (GHI) is the sunlight power reaching a flat, level surface, measured in watts per square metre (W/m²).
- Global Tilted Irradiance (GTI) Global tilted irradiance (GTI, also called plane-of-array or POA irradiance) is the sunlight power on a tilted surface.
- Irradiation (Insolation) Irradiation (also called insolation) is the sun’s energy on one square metre over a period.
- Meteonorm Meteonorm is Meteotest’s global weather and solar-resource dataset, sold as Meteonorm Climate.
- National Solar Radiation Database (NSRDB) The National Solar Radiation Database (NSRDB) is a free, satellite-modelled record of sunlight and weather from NREL, now the National Laboratory of…
- Near Shading vs Far Shading Near shading is shade from objects close to an array, such as chimneys, dormers, trees and other rows, which falls on some modules.
- Peak Sun Hours (PSH) Peak sun hours (PSH, also called sun hours) are a day’s solar energy per square metre in kWh/m², stated as hours at 1,000 W/m².
- Photovoltaic Geographical Information System (PVGIS) PVGIS (Photovoltaic Geographical Information System) is the European Commission’s free web tool for solar radiation data and PV yield estimates.
- Plane-of-Array Irradiance (POA) Plane-of-array irradiance (POA, also called in-plane irradiance) is the sunlight power reaching the tilted surface of a PV array, in W/m².
- Shade Report A shade report (or shading report) is the document that records how much shade cuts the sunlight reaching a roof or array.
- Soiling Soiling (also called dirt loss) is the energy a solar array loses when dust, pollen, droppings or other deposits build up on its glass.
- Solar Access Solar access (also called solar access value) is the share of a point’s unshaded yearly sunlight that still arrives after shade.
- Solar Irradiance Solar irradiance is the rate at which sunlight energy reaches a surface, measured in watts per square metre (W/m²).
- Sun Path Diagram A sun path diagram is a chart of the sun’s azimuth and elevation through the year at one latitude.
- Typical Meteorological Year (TMY) A typical meteorological year (TMY, also called a typical year file) is an 8,760-hour weather file built from 12 real months from different years.
Hardware and components 17
- AC vs DC Power AC vs DC power describes the two kinds of current in a solar system.
- Balance of System (BOS) Balance of system (BOS, also written balance of systems) is a label for the equipment, and sometimes the costs, around the solar modules.
- Bifacial Module A bifacial module (also called a double-sided panel) is a PV module whose cells make power from light on both faces.
- IEC 61215 / IEC 61730 IEC 61215 and IEC 61730 are the two international standards that qualify a PV module.
- Inverter An inverter (also called a PV or solar inverter) converts DC power from solar modules into AC power for a building or the grid.
- IP Rating (Ingress Protection) An IP rating (ingress protection rating, also called IP code) is a two-digit code from IEC 60529.
- Monocrystalline vs Polycrystalline Silicon Monocrystalline silicon is cut from a single crystal pulled from molten silicon, while polycrystalline (multicrystalline) silicon is cast as a block…
- N-Type, TOPCon and HJT (Solar Cell Technologies) N-type, TOPCon and HJT describe modern solar cells.
- Peak Watt (Wp) Peak watt (Wp, also called watt-peak) is a module’s rated power at standard test conditions (1,000 W/m², 25 °C cell).
- PERC and Half-Cut Cells PERC and half-cut cells are separate features, so what a sheet says about one tells you nothing about the other.
- Smart Meter / CT Clamp in Solar Monitoring A CT (current transformer) clamp clips round a wire so a gateway can read grid import and export.
- Solar Junction Box A solar junction box (also called a J-box) is the sealed enclosure on the back of a solar module.
- Solar Panel (Module) A solar panel, also called a solar module or PV module, is a sealed unit of linked solar cells behind front glass.
- Solar Tracker A solar tracker, also called a sun tracker, is a mount that turns PV modules during the day to follow the sun.
- STC (Standard Test Conditions) Standard test conditions (STC) are the lab conditions used to rate a solar module.
- String Inverter A string inverter converts DC from modules wired in series strings into AC for a whole array.
- Wattage (W), Kilowatt (kW) and kWp in Solar Wattage is power in watts (W), and a kilowatt (kW) is 1,000 W.
Monitoring, O&M and asset management 17
- Availability (Technical vs Contractual) in Solar O&M Availability in solar O&M is the share of sunlit time, or of expected energy, during which a PV plant or component could produce power.
- Computerised Maintenance Management System (CMMS) A CMMS (computerised maintenance management system) is software that keeps 5 linked records for a plant: assets, work orders, preventive schedules…
- Curtailment in Solar Curtailment in solar is a cut in a plant’s output below what the sunlight allows, caused by a grid operator, a market signal or a site limit.
- Data Logger (Gateway) in Solar Monitoring A data logger (gateway) is the on-site device that polls inverters, meters and weather stations over links such as RS-485 Modbus.
- Digital Twin for a Solar Plant A digital twin of a solar plant is a model of the plant as built, calibrated on measured data.
- Fleet Monitoring Fleet monitoring (also called portfolio monitoring) is watching many PV sites from one view.
- Module-Level Monitoring Module-level monitoring (also called panel-level monitoring) is reading power, voltage or current from each solar module instead of only the string…
- Performance Guarantee in Solar A performance guarantee (also called a production guarantee) is a contract promise that a PV plant will hit a set result, usually annual kWh.
- Pyranometer / Irradiance Sensor A pyranometer is a sensor that measures the sunlight reaching a surface, in W/m².
- Remote Diagnostics / Remote Configuration Remote diagnostics means reading a solar device’s faults over the internet.
- Solar Asset Management Solar asset management is the owner’s side of running a PV plant as an investment.
- Solar KPI Dashboard A solar KPI dashboard (key performance indicator dashboard, also a scorecard) shows a solar company’s few key numbers on one screen.
- Solar Monitoring Alert (Alerts and Alarms) A solar monitoring alert (or alarm) is an automatic message a monitoring platform sends when system data breaks a rule.
- Solar Monitoring Software Solar monitoring software (also called a monitoring platform or portal) collects readings from one or more PV sites and stores them.
- Solar Operations and Maintenance (O&M) Solar O&M (operations and maintenance) is the monitoring, inspection and repair work that keeps a PV plant producing.
- Supervisory Control and Data Acquisition (SCADA) Supervisory control and data acquisition (SCADA) polls plant devices such as inverters, stores their readings and sends commands back.
- Work Order A work order is the record of one job: what to do, where, who does it, by when, and what was found.
Energy simulation and yield 15
- 8760 Hourly Simulation An 8760 hourly simulation (also called an 8,760-hour simulation) models a solar system for every hour of a year.
- Ambient and Cell Temperature Ambient temperature is the air around a solar array.
- Bankable Energy Yield Bankable energy yield is a solar plant’s expected annual energy, reported in a form a lender can rely on.
- Capacity Factor Capacity factor is actual energy over a period divided by the energy a plant would make at rated capacity for every hour.
- Capacity Utilisation Factor (CUF) Capacity utilisation factor (CUF) is the Indian name for capacity factor: actual energy divided by the energy at full rated capacity over the same…
- Degradation Rate Degradation rate is the yearly fall in a PV module’s or system’s output, usually given in percent per year.
- Derate Factor A derate factor is one multiplier that bundles losses such as soiling, shading and wiring.
- Incidence Angle Modifier (IAM) IAM (incidence angle modifier) is the share of sunlight a module lets through to its cells when light strikes at an angle.
- NOCT / NMOT (Nominal Operating Cell Temperature) NOCT (nominal operating cell temperature) is the cell temperature a module reaches at 800 W/m², 20 °C air and 1 m/s wind.
- Performance Ratio (PR) Performance ratio (PR, also called quality factor) is the AC energy a PV system delivers divided by the ideal output at its nameplate rating.
- PVsyst Report A PVsyst report is the printable record of one PVsyst yield simulation for one project variant.
- Solar Power Forecasting Solar power forecasting (also called PV forecasting) predicts how much electricity a solar plant will produce over a coming period.
- Specific Yield (kWh/kWp) Specific yield is a PV system’s annual AC energy divided by its DC rating at STC, in kWh per kWp.
- System Loss Diagram (Loss Waterfall) A system loss diagram (loss waterfall) lists every energy loss between sunlight on the array and energy to the grid, in order.
- Temperature Coefficient (Solar Panel) A temperature coefficient is the change in a module’s Pmax, Voc or Isc per 1 °C (or 1 K) of cell temperature, quoted from 25 °C.
Project and field operations 14
- Change Order A change order is a written change to a signed contract’s scope, price or schedule, agreed by the parties.
- Commissioning Commissioning (also called PV system commissioning) is the process of proving a solar system is built and working as designed.
- Crew Management Crew management is how a solar business builds, assigns and tracks its install and service crews.
- ERP (Enterprise Resource Planning) ERP (enterprise resource planning) is business software that keeps 6 areas (finance, purchasing, stock, projects, service and payroll) in one shared…
- Field Service Management (FSM) Field service management (FSM, often sold as field service software) is the coordination of staff and equipment for work at customer sites.
- Handover Pack and As-Built Documentation A handover pack (also called a closeout pack) is the set of records given to the owner when a solar job ends.
- Install Stage (Installation Workflow) The install stage (also called the installation workflow) is where the crew builds the solar system on site, from mounting to commissioning.
- Inventory Management Inventory management (also called stock control) is tracking what parts a solar company holds, where they sit and which job each is for.
- Job Costing Job costing (also called job cost accounting) means recording the cost of each job on its own and comparing it with the estimate.
- Procurement and a Purchase Order (PO) Procurement is how a solar company buys the equipment and materials its jobs need.
- Scheduling and Dispatch in Solar Scheduling and dispatch is a 2-step routine for field jobs.
- Solar Photo Documentation (Site Photos) Solar photo documentation (also called site photos or a photo log) is the labelled photo record of a job at 4 stages: survey, install, inspection and…
- Solar Project Management Software Solar project management software tracks each solar job from signed contract to handover in stages.
- Subcontractor Management Subcontractor management is how a solar installer or EPC signs up, checks, books, pays and reviews the outside firms (subs) that do part of a job.
Proposals and sales 12
- Adder in Solar An adder (also called a price adder) is a priced extra on top of the base price per watt, like trenching or a panel upgrade.
- Canvassing App A canvassing app (also called a door-knocking or D2D app) is a phone app that solar setters use to log every door they knock.
- Close Rate (Conversion Rate) Close rate (the final-step conversion rate, sometimes called win rate) is the share of a starting group that ends in a signed contract.
- Dealer Fee A dealer fee (or financing fee) is a charge a solar lender builds into the loan principal, so the customer repays it with interest.
- Instant Estimate (Quote Calculator) in Solar An instant estimate in solar (also called a solar quote calculator) is a website widget.
- Interactive Web Proposal An interactive web proposal (or online proposal) is a solar quote the customer opens through a web link instead of a PDF.
- Price per Watt (Cost per Watt) in Solar Price per watt (PPW, sometimes called cost per watt) is a solar system’s price divided by its size in watts, usually DC watts.
- Redline Pricing (Redline Commission) Redline pricing is a solar sales pay plan where the company sets a minimum price per watt and the rep keeps everything above it.
- Sales Commission Tracking Sales commission tracking is the ledger of what each solar sale earned a rep, what was paid and what was clawed back.
- Solar Proposal Software Solar proposal software (also called a solar sales proposal tool) turns a finished design, a price and finance options into one customer proposal.
- Utility Bill Analysis (and Bill Offset) Utility bill analysis is reading a customer’s electric bills for annual kWh, rate plan and fixed charges, then sizing solar to match.
- White-Label (Branded) Proposal A white-label (branded) proposal is a solar quote that shows your brand, not the software maker’s.
CRM & lead management 10
- Drip Campaign (Nurture Sequence) A drip campaign (also called a nurture sequence) is a set of timed messages for a lead not ready to buy.
- Lead Management Lead management (also called sales lead management) is how an installer handles each enquiry in 5 steps: capture, qualify, assign, follow up and…
- Lead Routing (Round Robin) Lead routing (or lead assignment, lead distribution) is the rule that picks the sales rep for each new enquiry.
- Lead Scoring Lead scoring ranks each enquiry with points for 2 kinds of signal.
- Review Management Review management is how a solar installer asks for, collects, monitors and replies to customer reviews on Google, Yelp and solar review sites.
- Solar CRM Solar CRM (customer relationship management software for solar companies) is the system of record for sales.
- Solar Customer Portal A solar customer portal is a secure login where a customer sees one project: stage, documents and messages.
- Solar Sales Pipeline A solar sales pipeline (also called a deal pipeline) is the list of open sales opportunities at an installer.
- Speed to Lead Speed to lead (or lead response time) is how long a solar installer takes to make first human contact with a new enquiry, like a call or text.
- Workflow Automation in Solar Workflow automation (a rule or workflow in most tools) is software that runs set actions when a trigger fires and its conditions are true.
Permitting and interconnection 10
- Equipment Datasheet (Spec Sheet) An equipment datasheet (spec sheet, also called a cut sheet) is the manufacturer’s document of one product’s rated values, limits and listings.
- Hosting Capacity Map A hosting capacity map (also called an integration capacity map) shows how much distributed generation each feeder or line section can take before…
- IEEE 1547 IEEE 1547 is the US standard for connecting solar, batteries and other distributed generators to the distribution grid.
- Interconnection Queue An interconnection queue (generator queue) is the ordered list of generation and storage projects waiting to connect to the grid.
- PE Stamp (Engineering Stamp) A PE stamp (professional engineer stamp, also called an engineering stamp or seal) is a licensed engineer’s seal, signature and date on plans or…
- PTO (Permission to Operate) PTO (permission to operate, also called the PTO letter) is a utility’s notice that an installed solar system may be switched on and connected to the…
- Solar Labels and Placards Solar labels and placards are the warning signs an installer fixes to disconnects, the rapid shutdown switch, DC conduit and the main panel.
- Solar Site Plan A solar site plan, also called a plot plan, is a scaled, top-down permit drawing of the lot, buildings, array and equipment.
- SolarAPP+ SolarAPP+ is an online platform that automates permit review for residential rooftop solar and storage in participating US jurisdictions.
- UL 1741 and UL 9540 UL 1741 is the US safety standard for inverters, converters and charge controllers, and UL 9540 is the standard for complete energy storage systems.
Regional rules and programmes 10
- ALMM (Approved List of Models and Manufacturers) ALMM (Approved List of Models and Manufacturers) is the list India’s Ministry of New and Renewable Energy keeps of approved solar module and cell…
- DISCOM and Net Metering Approval (India) DISCOM and net metering approval (India) is the sign-off a state distribution company (DISCOM) gives to connect a rooftop solar system and fit its…
- DNO? G98 and G99 Explained (UK) DNO (distribution network operator) is the company that runs the local electricity network.
- Domestic Content Bonus The domestic content bonus is an extra US federal tax credit for clean energy projects built with enough US-made steel, iron and manufactured…
- Gross Metering Gross metering, also called buy-all, sell-all, is a billing setup with two meters.
- MCS Certification (UK) MCS certification (Microgeneration Certification Scheme) is the UK quality mark for small-scale renewables.
- PM Surya Ghar: Muft Bijli Yojana PM Surya Ghar: Muft Bijli Yojana is India’s central subsidy scheme for home rooftop solar, launched in February 2024.
- PM-KUSUM (India’s Farm Solar Scheme) PM-KUSUM is India’s central scheme for solar on farms, approved in February 2019.
- Renewable Portfolio Standard (RPS) A renewable portfolio standard (RPS) is a US state rule.
- Small-Scale Technology Certificate (STC) in Australia A small-scale technology certificate in Australia (STC) is a tradable certificate.
Utility-scale development and GIS 10
- Agrivoltaics Agrivoltaics (also called agri-PV or agrophotovoltaics, APV) is farming or grazing on the same land as solar panels, under them or between the rows.
- Cable Routing and Trenching in Solar Cable routing and trenching (also called cable layout) is planning the path of each DC and AC cable and the trenches that hold them.
- Earthworks and Grading Earthworks and grading (also called site grading or cut and fill) is the clearing, digging, filling and shaping of ground to reach design levels.
- Floating Solar (FPV) Floating solar (floating photovoltaics, or FPV) is a PV plant mounted on floats and moored on a reservoir, lake or other still water body.
- GIS (Geographic Information System) GIS (geographic information system) is software that stores, measures and maps location-based data as layers.
- Land Parcel Data Land parcel data (also called cadastral or tax parcel data) maps property outlines and links each polygon to county records.
- Site Selection Software Site selection software, also called solar siting software, screens land for solar projects against map layers such as parcel size, slope, flood…
- Solar Feasibility Study A solar feasibility study (also called a viability study) checks whether a proposed solar project can be built, connected and paid for.
- Topography and Terrain Modelling Topography and terrain modelling (or ground-surface modelling) turns survey heights into a digital elevation model.
- Utility-Scale Layout Optimisation Utility-scale layout optimisation is choosing row pitch (GCR), tilt, block size and cable routes for the lowest cost per kWh.
Inspection and drones 7
- Anomaly Classification in Solar Inspection Anomaly classification is sorting each finding in a thermal or visual PV inspection by type and severity.
- Bypass Diode Failure Bypass diode failure is when a diode in a PV module’s junction box no longer works as designed.
- Drone Inspection for Solar PV Plants Drone inspection (also called aerial thermography) is flying a drone with a thermal camera over a PV plant to find faulty modules and strings.
- Electroluminescence (EL) Testing Electroluminescence (EL) testing, also called EL imaging, passes forward current through a PV module so its cells glow in near-infrared light that a…
- I-V Curve Tracing I-V curve tracing measures a module or string’s current at every voltage from short circuit to open circuit.
- Orthomosaic An orthomosaic is a top-down map stitched from overlapping drone photos and corrected for tilt and height, so its scale is uniform and you can…
- Thermal (Infrared) Inspection for Solar PV Thermal inspection for solar PV (infrared or IR thermography) is photographing a PV array with a thermal camera to find parts that run hotter than…
No terms match “”.
Try a shorter word, an acronym such as PTO or NEC, or browse a category.